Quality Control and Test Methods
The method set
- ASTM D-281, ISO 787-9 and ISO 787-10 — pigment test methods used on incoming and finished material
- ISO 7724 — colour measurement (colorimetry)
- DIN 5033 — colour measurement, illuminants and observer conditions
- CF-32 and CF-33 — heat resistance: colour difference after thermal exposure
- EN 71-3 — migration of certain elements (toy safety)
- RoHS — restriction of hazardous substances in electrical equipment
The instruments behind the numbers
The methods are only as good as the equipment that runs them, and the same instruments are used for every grade in the range. Colour is read on a spectrophotometer under a defined illuminant and observer. Heat resistance is run in a muffle furnace, with the sample held at 800 °C for 60 minutes and measured against an unheated reference. Weathering runs on a xenon-arc lamp, which delivers the 5000 h exposure behind the 30+ year claim, and light fastness is assessed against the blue wool scale.
Chemical resistance is checked by immersion across the pH range, and pigment identity and composition are confirmed before release. Keeping one instrument set for reference standards, production samples and weathered samples is what makes a ΔE*ab figure comparable across those three contexts.
Heat resistance: CF-33 at 800 °C
Heat resistance is the property that separates a CICP pigment from every organic colourant, and it is measured rather than asserted. A sample is held at 800 °C for 60 minutes in a muffle furnace and the colour difference is read against the unheated reference. The specification is ΔE*ab ≤3.0.
CF-32 applies the same thermal discipline as a companion method, so a grade can be characterised across a temperature series rather than at a single point. Both are reported on the grade TDS and on the batch certificate where the application calls for it.
Colour measurement: ISO 7724 and DIN 5033
Colour is measured on a spectrophotometer under a defined illuminant and observer, to ISO 7724 and DIN 5033. The same instrument set is used for incoming reference standards and for weathered samples, so a ΔE*ab figure means the same thing whether it comes from a production release, a heat-resistance test or a weathering programme.
Light fastness is assessed on the blue wool scale, where the range is rated grade 8. Weathering is run over 5000 h of xenon-arc exposure, which underpins the 30+ year exterior claim and lets a formulator compare a new grade against a known one on the same basis.
Chemical resistance and regulatory testing
Chemical resistance is verified across pH 1–14, which spans the acid end of acid rain and industrial cleaning and the alkaline end of fresh concrete and detergent exposure. The test is the reason the CICP range can be specified for construction, ceramics and exterior coatings with one durability statement rather than three.
EN 71-3 covers the migration of certain elements for toy and child-contact applications, and RoHS covers restricted substances for electrical and electronic equipment. Declarations for both are issued per grade where the application requires them, alongside the batch COA and the safety data sheet.
Frequently asked questions
How is heat resistance measured?
By CF-33: the pigment is held at 800 °C for 60 minutes and the colour difference is measured against the unheated reference. The specification is ΔE*ab ≤3.0.
What does grade 8 light fastness mean?
It is the top of the blue wool scale, meaning the pigment shows no perceptible change under the test exposure. It is one of the inputs behind the 30+ year weathering rating.
Are EN 71-3 and RoHS declarations available?
Yes, for grades where the application requires them. They are issued alongside the batch COA and the safety data sheet.